Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Acupuncture & Moxibustion ; (12): 305-308, 2023.
Artigo em Chinês | WPRIM | ID: wpr-969989

RESUMO

OBJECTIVE@#To compare the effect on facial acupoint temperature between acupuncture at Houxi (SI 3) and Dazhui (GV 14) so as to verify "Houxi (SI 3) communicating the governor vessel" based on the infrared thermal imaging technology.@*METHODS@#Thirty-five healthy subjects (5 cases dropped off) were collected and before-after study in the same subject was adopted. The subjects were successively assigned into a sham-acupuncture group, a Houxi group, a Wangu group and a Dazhui group. Sham-acupuncture at Houxi (SI 3) on the left, acupuncture at Houxi (SI 3) on the left, Wangu (SI 4) on the left and Dazhui (GV 14) were given respectively. One intervention was given and the needles were retained for 30 min in each group. 30 min before and after acupuncture, the infrared thermal images of the face were collected, and the facial temperature was compared among the following 5 acupoints, i.e. Yintang (GV 24+), Suliao (GV 25), Shuigou (GV 26), Duiduan (GV 27) and Chengjiang (CV 24).@*RESULTS@#After acupuncture, the facial temperature at Yintang (GV 24+) and Chengjiang (CV 24) was increased compared before acupuncture in the sham-acupuncture group (P<0.01, P<0.05). The facial temperature at Suliao (GV 25) in the Houxi group was reduced after acupuncture (P<0.05). In the Wangu group, the temperature at Yintang (GV 24+) was increased compared before acupuncture (P<0.01). The facial temperature was increased at Duiduan (GV 27) and Chengjiang (CV 24) compared before acupuncture in the Dazhui group (P<0.01, P<0.05). The differences of facial temperature at Chengjiang (CV 24) and Suliao (GV 25) after acupuncture were larger than before acupuncture in the Houxi group and the Dazhui group (P<0.01). In comparison with the temperature at Suliao (GV 25) of the same group, the differences of facial temperature before and after acupuncture at Yintang (GV 24+), Shuigou (GV 26), Duiduan (GV 27) and Chengjiang (CV 24) were increased in the Houxi group (P<0.01, P<0.05); while, the increase was also obtained at Yintang (GV 24+), Shuigou (GV 26), Duiduan (GV 27) and Chengjiang (CV 24) in the Dazhui group (P<0.05, P<0.01). The difference of facial temperature at Yintang (GV 24+) before and after acupuncture was increased compared with Suliao (GV 25) in the Wangu group (P<0.05).@*CONCLUSION@#Acupuncture at Houxi (SI 3) generates a similar thermal effect as Dazhui (GV 14). It regulates and dissipates the core temperature to "govern the yang qi of the whole body".


Assuntos
Humanos , Terapia por Acupuntura , Pontos de Acupuntura , Voluntários Saudáveis , Agulhas , Tecnologia
2.
Journal of Peking University(Health Sciences) ; (6): 187-192, 2020.
Artigo em Chinês | WPRIM | ID: wpr-941987

RESUMO

OBJECTIVE@#To explore the possibility of the Smile Lite MDP (Smile Lite Mobile Dental Photograph) portable dental photography system applying in anterior teeth aesthetic photography, and to provide the chance to simplify aesthetic photography process and facilitate communication among patients, dentists and dental technitians.@*METHODS@#The Smile Lite MDP photography system combined with the smartphone were used to photograph the front occlusal phase photos of anterior teeth. The photographic conditions including the color temperature parameter, the Smile Lite MDP light position and the intensity settings were explored. The best photographic conditions were chosen by blind evaluation within experienced dentists and technicians through the method of the visual analogue scale/score (VAS) evaluation, which went through statistical analysis to figure out the optimum photograghic conditions. Smile Lite MDP photography system was used to photograph the front occlusal phase photos of anterior teeth under the optimum parameter by different magnifications. The width/height ratio of the central incisor and the front width ratio of the upper anterior teeth in those photos were measured and calculated respectively. The accuracy of the anterior teeth photos taken by Smile Lite MDP photography system was analyzed based on the photographs taken by digital single lens reflex (DSLR) camera.@*RESULTS@#The optimum color temperature parameter of Smile Lite MDP portable camera system was 5 000 K, the optimum magnification was 4 times, the best light position was the side lights of Smile Lite MDP, the optimum intensity of lights was 2 grades. Photos taken by the optimum parameters won the highest score during the VAS evaluation and the result of statistical analysis had significant difference compared with other groups (P<0.05). When comparing the photos of the upper anterior teeth taken by the Smile Lite MDP portable photography system using 4 times magnification or by DSLR using the standard parameters, there was no significant difference neither in the width/hieght ratio of the central incisor nor in the front width ratio of the upper anterior teeth (P>0.05).@*CONCLUSION@#The Smile Lite MDP portable dental photography system applying in anterior teeth aesthetic analysis photography was capable to show the color and shape of anterior teeth in an accurate way by using the right photography parameters. Therefore, Smile Lite MDP portable dental photography system was considered to be a simple and easy photographic tool in clinical work.


Assuntos
Humanos , Estética , Estética Dentária , Incisivo , Fotografação , Sorriso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA